Evaluation of the SD Bioline Hiv/Syphilis Duo and SD Bioline Syphilis 3.0 Test Kits for Hiv/Aids and Syphilis Screening at Komfo Anokye Teaching Hospital, Kumasi

dc.contributor.authorOpoku-Nketiah, Bright
dc.date.accessioned2014-07-29T11:26:48Z
dc.date.accessioned2023-04-20T11:32:04Z
dc.date.available2014-07-29T11:26:48Z
dc.date.available2023-04-20T11:32:04Z
dc.date.issued2014-07-29
dc.descriptionA thesis submitted to the Department of Clinical Microbiology, Kwame Nkrumah University of Science and Technology, Kumasi in partial fulfilment of the requirements for the degree of Master of Science, May-2014en_US
dc.description.abstractDiagnostic tests are needed for the control of sexually transmitted infections, as many infected individuals are asymptomatic. Rapid advances in molecular biology have led to the development of sensitive and specific diagnostic tests. New diagnostics tests must be evaluated in the situations in which they will be deployed. This study evaluated the SD Bioline HIV/syphilis Duo and the SD Bioline syphilis 3.0 test kits in HIV and syphilis testing. A total of 644 well characterised, archived serum samples were used. IMMUTREP® RPR, IMMUTREP® TPHA, Genscreen ULTRA HIV Ag-Ab and First Response® HIV 1-2-0 were used as gold standards. All 644 samples were assayed for the presence of antibodies to HIV and T. Pallidum by the SD Bioline HIV/syphilis Duo, the SD Bioline syphilis 3.0 and the Abbott DetermineTM Syphilis TP. The sensitivity, specificity, positive and negative predictive values of the SD Bioline syphilis 3.0 test kits were 91.67%, 100.00%, 100.00% and 89.29% respectively. The Abbott DetermineTM Syphilis TP had 75.69%, 100.00%, 100.00% and 74.07% respectively. In HIV testing, the SD Bioline HIV/syphilis Duo had 100.00%, 100.00%, 100.00% and 100.00% respectively. In syphilis testing, it had 100.00%, 99.33%, 99.60% and 100.00% respectively. The kappa value for SD Bioline syphilis 3.0 and Abbott DetermineTM Syphilis TP were 0.90 and 0.72 respectively, whiles the SD Bioline HIV/syphilis Duo had 1.00 and 0.99 in HIV and syphilis testing respectively. The SD Bioline HIV/syphilis Duo and SD Bioline syphilis 3.0 compared favourably with the gold standards. They are highly specific and very sensitive. They can be performed in clinics and/or hospitals without laboratory training and require no equipment or refrigeration. The SD Bioline HIV/syphilis Duo can be used for simultaneous screening of HIV and syphilis at antenatal clinics in Ghana. This would increase the coverage of HIV and syphilis screening, which will also increase the proportion of cases treated, facilitating the elimination of mother-to-child transmission of HIV and congenital syphilis.en_US
dc.description.sponsorshipKNUSTen_US
dc.identifier.urihttps://ir.knust.edu.gh/handle/123456789/6202
dc.language.isoenen_US
dc.subjectGold Standarden_US
dc.subjectSensitivityen_US
dc.subjectSpecificityen_US
dc.subjectPositive Predictive Valueen_US
dc.subjectNegative Predictive Valueen_US
dc.subjectKappa Coefficienten_US
dc.titleEvaluation of the SD Bioline Hiv/Syphilis Duo and SD Bioline Syphilis 3.0 Test Kits for Hiv/Aids and Syphilis Screening at Komfo Anokye Teaching Hospital, Kumasien_US
dc.typeThesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bright Opoku-Nketiah.pdf
Size:
1.04 MB
Format:
Adobe Portable Document Format
Description:
Full Thesis
License bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.73 KB
Format:
Item-specific license agreed to upon submission
Description:
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: